Follow

Reliability Testing

We know our products play vital roles in the productions of our customers. Durability and consistent, robust performance are much more than just adjectives for your business and ours. For this reason, all NewTek products undergo rigorous reliability testing to ensure they meet our exacting test standards. For NewTek 3Play, the following standards are applicable:

Test Parameter Evaluation Standard
   
Temperature Mil-Std-810F Part 2, Sections 501 & 502
     Ambient Operating 0°C and +40°C
     Ambient Non-Operating -10°C and +55°C
Humidity Mil-STD 810, IEC 60068-2-38
     Ambient Operating 20% to 90%
     Ambient Non-Operating 20% to 95%
Vibration ASTM D3580-95; Mil-STD 810
     Sinusoidal Exceeds ASTM D3580-95 Paragraph 10.4: 3 Hz to 500 Hz
     Random Mil-Std 810F Part 2.2.2, 60 minutes each axis, Section 514.5 C-VII
Electrostatic Discharge IEC 61000-4-2
Air Discharge 8K Volts
Contact 4K Volts

 

Appendix D

For more information please download the entire document at new.tk/rt-m